RFC589 CCN NETRJS server messages to remote user

0589 CCN NETRJS server messages to remote user. R.T. Braden. November 1973. (Format: TXT=7998 bytes) (Status: UNKNOWN)

日本語訳
RFC一覧

参照

Received at NIC 14-DEC-73                               Robert T. Braden
RFC589                                                          UCLA/CCN
NIC #20268                                             November 26, 1973





                           CCN NETRJS SERVER
                        MESSAGES TO REMOTE USER





A.  _I_N_I_T_I_A_L _C_O_N_N_E_C_T_I_O_N, _S_I_G_N_O_N, _A_N_D _S_I_G_N_O_F_F

     1.   If CCN refuses an ICP to a NETRJS socket, it means either that
          there is no free core within the NCP region, or that CCN's
          software is crashing.

     2.   Once ICP is completed, CCN might send the user one of the fol-
          lowing messages and close the Telnet connections:

          NRJ110I NETRJS PORTS BUSY.  TRY LATER

               This may be expected occasionally; frequent occurrance
               should be reported to CCN User Relations (825-7548), or
               to BELL@CCN.

          NRJ111I RJS NOT UP, TRY LATER

     3.   Normally, however, the user will receive a READY message:

               NRJ876R CCN NETRJS READY.  ENTER SIGNON

          If the user sends no operator input for 3 minutes, CCN will
          send:

               NRJ308R SIGNON TIMEOUT EXCEEDED

               NRJ205R NETRJS SESSION TERMINATED

          and close the Telnet connection.  If he sends an invalid SIG-
          NON command, he will receive the message:

               NRJ307R INVALID SIGNON, RE-ENTER




                                                                [Page 1]

NIC #20268
                                                                     P.2


7          Finally, a valid signon will be acknowledged by RJS with the
          message:

               RJS750I TERMINAL -termid- HAS SIGNED ONTO RJS

     4.   If the user terminates the session by entering a SIGNOFF com-
          mand, NETRJS will wait until all data transfer has completed
          before sending the message:

               NRJ205R NETRJS SESSION TERMINATED

          and closing the Telnet connection.


B.  _R_E_M_O_T_E _S_I_T_E _O_R _N_E_T_W_O_R_K _F_A_I_L_U_R_E_S


     1.   During data transfer, the user must be reasonably responsive.
          If not, CCN will close the data transfer connection and send
          the remote operator message:

               NRJ504I DATA TRANSFER TIMEOUT FOR THE -device-, -termid-


                    a)   if -device- is PRINTER or PUNCH, user site
                         stopped accepting bits (sending "allocates")
                         for over 5 minutes.

                    b)   if -device- is READER, user site left reader
                         connection open without sending any bits for 5
                         minutes.

     2.   During data transfer on the CR connection, CCN may detect an
          incorrect header or record, presumably due to user site
          software or Network transmission error.  The following mes-
          sages beginning with the word "BAD" will follow an NRJ512I
          message containing the faulty header in hex:

               NRJ505I BAD HEADER SEQUENCE FOR NETRJS READER

                    Sequence number in transaction header does not match
                    internal counter of records passed.

               NRJ506I BAD HEADER LENGTH FOR NETRJS READER

                    Length given in header exceeds 880 bytes.





                                                                [Page 2]

NIC #20268
                                                                     P.3


7               NRJ507I BAD HEADER TYPE FOR NETRJS READER

                    Type code in header is not X'FF' (data) or X'FE'
                    (end-of-data)

               NRJ511I BAD FILL BIT COUNT FOR NETRJS READER

                    The filler bit count in header is not a multiple of
                    8.

     3.   If the header is correct but a data record is faulty, the fol-
          lowing message will be sent to a remote user:

               NRJ602I line STREAM ERROR - READER, -code-

                    A protocol error was detected in the READER stream.
                    CCN will close the stream and ready it to be reo-
                    pened so the remote user may retry the data transfer
                    operation.  The valid -code- values are:

     _C_O_D_E            _E_R_R_O_R

       1             Device id byte has high bit off.

       2             End of transaction in the middle of a data line.

       3             Truncated input line longer than 255 bytes.

       4             In compressed text, string control byte has high
                     bit off.

       5             In compressed text, duplicate blank string extends
                     line longer than 255 bytes.

       6             In compressed text, duplicate character string
                     extends line longer than 255 bytes.

       7             In compressed text, character string extends line
                     longer than 255 bytes.


     4.   Finally, if the user aborts his data transfer, he receives the
          message:

               NRJ502I NETRJS -device- DATA TRANSFER ABORTED BY USER
               -termid-.





                                                                [Page 3]

NIC #20268
                                                                     P.4


7C.  _C_C_N _F_A_I_L_U_R_E_S


     1.   The CCN operator can cancel a NETRJS session, aborting any
          open data transfer streams and sending the message:

               NRJ204I NETRJS SESSION ABORTED BY CENTRAL OPERATOR, TERM=
               -termid-

     2.   Any of the following messages indicate a serious CCN Network
          software problem, and will cause the session to be aborted:

               NRJ106A NETRJS DEAD - EXCHANGE INOPERATIVE

               NRJ201A NETRJS DT SOCKET ERROR - BAD LISTEN

               NRJ208A NETRJS PROGRAM CHECK IN -device-, code=ccc

               NRJ209A NETRJS LOAD FAILED FOR -device-, code=xx

               NRJ304I RJS LINE HANDLER DEAD

               NRJ401I RJS LINE HANDLER DEAD

               NRJ402I RJS LINE HANDLER DEAD

          Any of these should be reported to CCN.

     3.   Besides global catastrophes like these above, the user might
          encounter a failure of a particular data transfer process.
          These do not terminate the session, only cause the data con-
          nection to be refused or terminated; the user can try again to
          open the data connection.  Repeated failure should be reported
          to CCN.

               NRJ501I NO CORE FOR DATA TRANSFER BUFFER -device-

               NRJ503I NO CORE FOR DATA TRANSFER WORKAREA -device-

               NRJ207I NO CORE FOR-device-DATA TRANSFER MODULE

                    Due to core memory limitations in CCN's NCP,
                    -device- cannot be started now.  The data transfer
                    connection indicated by -device- will be refused.
                    This may happen occasionally during active periods,
                    but repeated occurrences should be reported to CCN.





                                                                [Page 4]

NIC #20268
                                                                     P.5


7               NRJ509I -device- DATA TRANSFER DEAD

               NRJ510I -device- DATA TRANSFER DEAD

               NRJ602I line STREAM ERROR - PRINTER, -code-

               NRJ602I line STREAM ERROR - PUNCH, -code-

                    CCN data transfer failed, but recovery may be possi-
                    ble.  User may try again.


            [ This RFC was put into machine readable form for entry ]
            [ into the online RFC archives by Tony Hansen 10/98     ]





































                                                                [Page 5]

一覧

 RFC 1〜100  RFC 1401〜1500  RFC 2801〜2900  RFC 4201〜4300 
 RFC 101〜200  RFC 1501〜1600  RFC 2901〜3000  RFC 4301〜4400 
 RFC 201〜300  RFC 1601〜1700  RFC 3001〜3100  RFC 4401〜4500 
 RFC 301〜400  RFC 1701〜1800  RFC 3101〜3200  RFC 4501〜4600 
 RFC 401〜500  RFC 1801〜1900  RFC 3201〜3300  RFC 4601〜4700 
 RFC 501〜600  RFC 1901〜2000  RFC 3301〜3400  RFC 4701〜4800 
 RFC 601〜700  RFC 2001〜2100  RFC 3401〜3500  RFC 4801〜4900 
 RFC 701〜800  RFC 2101〜2200  RFC 3501〜3600  RFC 4901〜5000 
 RFC 801〜900  RFC 2201〜2300  RFC 3601〜3700  RFC 5001〜5100 
 RFC 901〜1000  RFC 2301〜2400  RFC 3701〜3800  RFC 5101〜5200 
 RFC 1001〜1100  RFC 2401〜2500  RFC 3801〜3900  RFC 5201〜5300 
 RFC 1101〜1200  RFC 2501〜2600  RFC 3901〜4000  RFC 5301〜5400 
 RFC 1201〜1300  RFC 2601〜2700  RFC 4001〜4100  RFC 5401〜5500 
 RFC 1301〜1400  RFC 2701〜2800  RFC 4101〜4200 

スポンサーリンク

IN演算子 入っているか

ホームページ製作・web系アプリ系の製作案件募集中です。

上に戻る